All Solutions

Wrong number of DOFs in initial value

Solution Number: 1182 Applies to: COMSOL Multiphysics Versions: All versions

The error "Wrong number of DOFs in initial value" occurs. The current solution or the stored solution has for some reason the wrong number of degrees of freedom, sometimes due to a change of the implementation of ...


Wrong Number of DOFs in Linearization Point

Solution Number: 1183 Applies to: COMSOL Multiphysics Versions: All versions

The error "Wrong number of DOFs in linearization point" occurs. The current solution or the stored solution has for some reason the wrong number of degrees of freedom, sometimes due to a change of the implementation of ...


Duplicate parameter/variable name

Solution Number: 1184 Applies to: COMSOL Multiphysics Versions: All versions

The error "Duplicate parameter/variable name" occurs. A parameter name or a variable name has at least two different definitions. For instance, the same variable name appears two or more times for a dependent variable, ...


Failed to Evaluate Variable

Solution Number: 1185 Applies to: COMSOL Multiphysics Versions: All versions

The error "Failed to evaluate variable" occurs. An error occurred when evaluating a variable. The domains in which COMSOL Multiphysics tried to evaluate the variable are indicated. Also, the error message shows the ...


Out of Memory During Assembly

Solution Number: 1186 Applies to: COMSOL Multiphysics Versions: All versions

The error "Out of memory during assembly" occurs. This error message indicates that your computer does not have enough RAM memory to assemble the numerical model which you are working with. There are two distinct, ...


Undefined Function Call

Solution Number: 1187 Applies to: COMSOL Multiphysics Versions: All versions

The error "Undefined function call" occurs. An expression in the model contains an undefined function name. Check that the function name is correct and that the function is in the COMSOL Multiphysics or MATLAB® path.


Internal evaluation error: unexpected NaN encountered

Solution Number: 1188 Applies to: COMSOL Multiphysics Versions: All versions

The error "Internal evaluation error: unexpected NaN encountered" occurs. This error occurs when Not-a-Number (NaN) values appear unexpectedly. Such values can be the result of floating-point operations such as 0/0, ...


Unsupported Integration Order

Solution Number: 1189 Applies to: COMSOL Multiphysics Versions: All versions

The error "Unsupported integration order" occurs. The integration order for the numerical quadrature is too high. For triangular elements the order can be up to 10, and for tetrahedral elements the order can be up to ...


Fatal error

Solution Number: 1190 Applies to: COMSOL Multiphysics Versions: All versions

A "Fatal error" occurs. If you receive this error, copy and paste the entire error message and send it to support@comsol.com along with ...


Segregated solver steps do not involve all components

Solution Number: 1191 Applies to: COMSOL Multiphysics Versions: All versions

An error "Segregated solver steps do not involve all components" occurs. The groups for the segregated solver do not include all dependent variables. One reason for this error could be that some boundary conditions ...